Configuration references · Compare each stated winding-rise and peak-duration basis. Agree final installation dimensions and operating conditions for your application.

Frame-size comparison / 115 mm stator OD

115 mm frameless torque motorsCompare stacks, winding current and CAD.

Compare 9 winding references across 3 mechanical configurations. The listed iron stacks are 13, 20, 26 mm; check each body maximum and the separate lead-routing space before evaluating a housing.

Review the 83.5 mm rotor-bore interface together with the customer shaft, retention and feedback hardware. Compare the actual 40-pole winding references, then resolve the 20/26 mm stack groups’ body-length questions and the individual speed reference before approving a drive or housing.

Source class: reviewed engineering documentation, not independent motor measurements. Each SKU keeps its own conditions and revision.

One mechanical referenceFTM-R114
FTM-R114 actual CAD reference for one of the 115 mm frameless motor configurations
Representative of FTM-R114 only; neutral CAD palette, not verified finish or a photograph of every model.
Stator OD
115mm
Rotor bore
83.5mm
Iron stacks
13 / 20 / 26mm
Winding references
9models

Screen your envelope across frames and compare up to four windings ↗

01 / Compare on an explicit basis

Check axial space before comparing torque.

Body limits exclude actual lead routing. The two continuous columns retain temperature-rise conditions and RMS current; neither establishes a loaded torque-speed point in your housing.

Scroll the table on narrow screens. Open a SKU for all electrical entries, timed peaks, CAD scope and direct PDF/STEP downloads.

Model / revisionStack / body maxBoreVoltage rangeContinuous / 55°C riseContinuous / 105°C riseNo-load speedDocumented mass
FTM-R114-W01 ↗
rev-a

Engineering review pending

13 / ≤23 mm83.5 mm12–80 V2.50 N·m / 2.04 A RMS4.20 N·m / 3.41 A RMS460 rpm439 g
FTM-R114-W02 ↗
rev-a

Engineering review pending

13 / ≤23 mm83.5 mm12–80 V2.50 N·m / 4.07 A RMS4.20 N·m / 6.82 A RMS920 rpm439 g
FTM-R114-W03 ↗
rev-a

Engineering review pending

13 / ≤23 mm83.5 mm12–80 V2.50 N·m / 8.14 A RMS4.20 N·m / 13.64 A RMS1760 rpm439 g
FTM-R115-W01 ↗
rev-a

Engineering review pending

20 / ≤30 mm

Drawing reference · body length disputed

83.5 mm12–80 V3.90 N·m / 2.04 A RMS6.40 N·m / 3.41 A RMS300 rpm649 g
FTM-R115-W02 ↗
rev-a

Engineering review pending

20 / ≤30 mm

Drawing reference · body length disputed

83.5 mm12–80 V3.90 N·m / 4.07 A RMS6.40 N·m / 6.82 A RMS600 rpm649 g
FTM-R115-W03 ↗
rev-a

Engineering review pending

20 / ≤30 mm

Drawing reference · body length disputed

83.5 mm12–80 V3.90 N·m / 8.14 A RMS6.40 N·m / 13.64 A RMS1100 rpm649 g
FTM-R116-W01 ↗
rev-a

Engineering review pending

26 / ≤36 mm

Drawing reference · body length disputed

83.5 mm12–80 V5.00 N·m / 2.04 A RMS8.40 N·m / 3.41 A RMS220 rpm829 g
FTM-R116-W02 ↗
rev-a

Engineering review pending

26 / ≤36 mm

Drawing reference · body length disputed

83.5 mm12–80 V5.00 N·m / 4.07 A RMS8.40 N·m / 6.82 A RMS450 rpm829 g
FTM-R116-W03 ↗
rev-a

Engineering review pending

26 / ≤36 mm

Drawing reference · body length disputed

83.5 mm12–80 V5.00 N·m / 8.14 A RMS8.40 N·m / 13.64 A RMS1100 rpm829 g

Documented values are generally ±10%. No-load speed is not loaded speed, listed mass is not an independently weighed complete assembly, and matching temperature-rise labels do not establish identical cooling. No compatibility score or drop-in approval is inferred.

02 / Inspect the actual axial configurations

Each mechanical reference has its own CAD.

Use the correct geometry and revision. Shared winding images describe the reviewed mechanical reference, not internal coil construction or identical mass.

Iron stack versus drawing body maximum, in millimetresReference lengths on one scale. Bars do not describe axial positions, end windings or installation clearance.Drawing reference lengths · mmFTM-R114≤23 mm body13 mm stackFTM-R115≤30 mm body20 mm stackBody length disputed · confirmation requiredFTM-R116≤36 mm body26 mm stackBody length disputed · confirmation required
Lengths use the same scale and remain in the HTML table above. Bars do not show assembly positions or approve a fit. Actual leads need separate space; scroll this diagram on narrow screens. Disputed body references remain provisional; see the open reviews above.
FTM-R114 isometric CAD showing the 13 mm iron-stack configuration
FTM-R114 / rev-a
13 mm stack · ≤23 mm drawing body · about 46 mm full CAD axial envelope with modeled leads.

FTM-R114-W01 / FTM-R114-W02 / FTM-R114-W03: Documented dimensions and ratings support initial selection. Confirm the configured winding, installation drawing and operating conditions for your application.

Inspect this model’s dimensions & STEP ↗
FTM-R115 isometric CAD showing the 20 mm iron-stack configuration
FTM-R115 / rev-a
20 mm stack · ≤30 mm drawing body · about 53 mm full CAD axial envelope with modeled leads.

FTM-R115-W01 / FTM-R115-W02 / FTM-R115-W03: Axial dimensions are documentation references for configuration discussion. The final body envelope, tolerances and lead exit must be specified on the configuration drawing; these references do not establish installation fit.

Inspect this model’s dimensions & STEP ↗
FTM-R116 isometric CAD showing the 26 mm iron-stack configuration
FTM-R116 / rev-a
26 mm stack · ≤36 mm drawing body · about 59 mm full CAD axial envelope with modeled leads.

FTM-R116-W01 / FTM-R116-W02 / FTM-R116-W03: Axial dimensions are documentation references for configuration discussion. The final body envelope, tolerances and lead exit must be specified on the configuration drawing; these references do not establish installation fit.

Inspect this model’s dimensions & STEP ↗

03 / Turn a candidate into an engineering brief

Fit, loaded point, duty and heat path.

Constrain the complete assembly

State maximum OD, minimum usable bore after the shaft/retention, motor body and complete wiring space. The iron stack cannot substitute for total length. Include fits and feedback hardware.

Review the winding with the drive

Provide loaded torque and speed, bus voltage and current convention. Compare resistance, inductance, constants and continuous/peak drive limits from each individual datasheet; no-load speed is only one reference entry.

Keep continuous and timed peak separate

Select an acceptable winding rise, ambient and housing heat path. Attach peak duration and recovery to torque. The documentation does not fully define repeated peak cycles or guarantee the same cooling across configurations.

Available-for-review customization includes winding/voltage matching, bore and interfaces, lead exit/length/connectors and temperature-sensor needs. Changes require a reviewed configuration, sample plan and confirmation drawing. MOQ, lead time and price are quoted against that configuration.

Before choosing a 115 mm frame.

Which engineering review remains open for FTM-R114-W01 / FTM-R114-W02 / FTM-R114-W03?

Documented dimensions and ratings support initial selection. Confirm the configured winding, installation drawing and operating conditions for your application. These reference values do not resolve open documentation questions or approve a fit or drive setting. Confirm the applicable configuration and documentation before selection.

Which engineering review remains open for FTM-R115-W01 / FTM-R115-W02 / FTM-R115-W03?

Axial dimensions are documentation references for configuration discussion. The final body envelope, tolerances and lead exit must be specified on the configuration drawing; these references do not establish installation fit. These reference values do not resolve open documentation questions or approve a fit or drive setting. Confirm the applicable configuration and documentation before selection.

Which engineering review remains open for FTM-R116-W01 / FTM-R116-W02 / FTM-R116-W03?

Axial dimensions are documentation references for configuration discussion. The final body envelope, tolerances and lead exit must be specified on the configuration drawing; these references do not establish installation fit. These reference values do not resolve open documentation questions or approve a fit or drive setting. Confirm the applicable configuration and documentation before selection.

What does 115 mm describe?

It is the stator outside-diameter reference, not the complete installed assembly. The body, customer housing, shaft retention, feedback and wiring need separate space and tolerance review.

Does the same outside diameter and bore mean the motors are interchangeable?

No. Compare iron stack, rotor length, full body and lead projection, fits and retention. Shared radial dimensions do not establish axial fit, drive settings or an approved replacement.

How should I choose between winding options?

Start with a loaded torque-speed point and the drive’s continuous/peak current definitions, then review bus voltage, duty cycle and heat path. A higher speed coefficient or no-load speed alone does not select the best winding.

Why are there two continuous torque conditions?

The entries use different winding temperature rises relative to ambient. They are not absolute winding-temperature limits. Identical labels do not prove identical cooling or test conditions; confirm the application heat path.

Can I use the largest peak torque for repeated motion?

Keep the specified two- or ten-second duration and current with the torque. Recovery time, ambient, housing cooling and winding limits are not fully established by those entries. Send the complete repeat cycle for review.

Where are the STEP files and customization details?

Open the exact model page for its applicable mechanical STEP, winding datasheet, revision and file checksums. Winding, interfaces and leads can be reviewed against your brief; the order configuration and commercial terms require confirmation.

04 / Request the configuration you need

Send the loaded duty and complete envelope.

A frame-size request alone is insufficient to confirm a winding. Include your heat path, drive definitions, peak/recovery cycle, shaft/feedback needs and quantities.

Email directly

If the form is unavailable, contact [email protected] or WhatsApp WhatsApp Engineering Support.

Turn selection requirements into an engineering review

A dimensional shortlist still needs winding, thermal and installation evidence for the actual assembly.

Look up a model, screen the envelope and compare winding referencesUse the record’s revision and open reviews; a shortlist is not engineering confirmation.