Custom configuration reference · Final axial envelope to be agreed on your configuration drawing.

Frameless motor reference / 115 mm frame

FTM-R116-W01115 mm frameless torque motor

FTM-R116-W01 is a 115 mm frameless motor reference with a 83.5 mm rotor bore and 26 mm iron stack. Its 5 rpm/V winding documents 5 N·m at 2.04 A RMS under the 55°C winding-rise condition. Use the references to discuss your winding, housing and duty cycle.

rev-a · Documentation reviewed 2026-10-31 · Standard configuration subject to order confirmation

Mechanical referenceFTM-R116
FTM-R116-W01 isometric CAD view showing the stator, rotor bore and modeled power leads
Actual CAD geometry · Neutral engineering palette · Product finishes are not verified. Shared mechanical reference across the listed winding options; not a winding-detail image.
Stator OD
115mm
Rotor bore
83.5mm
Iron stack
26mm
Final axial envelope
To agreeon drawing

01 / Choose the operating basis

Keep temperature rise and peak duration with the torque.

The same winding has different documented ratings under different limits. Start with your duty cycle and housing heat path.

Continuous torque by winding temperature rise

RiseTorqueRMS current
55°C5.00 N·m2.04 A
105°C8.40 N·m3.41 A

Peak torque by duration

DurationTorqueRMS peak current
10 s20.9 N·m9.13 A
2 s32.3 N·m18.26 A
FTM-R116-W01 discrete comparison of 55 and 105 degree temperature-rise ratings and 2 and 10 second peak torque
Separate scales compare the continuous pair and the peak pair. These are documented entries, not a torque–speed curve.

Documented performance and electrical entries are generally ±10%. Temperature rise is relative to ambient, not the absolute winding temperature. The source documentation does not fully define the housing heat sink, ambient temperature or repeated-peak recovery cycle. These ratings require application review; they are not independently measured results. Reference publication does not establish a configured production rating.

Axial dimensions are documentation references for configuration discussion. The final body envelope, tolerances and lead exit must be specified on the configuration drawing; these references do not establish installation fit.

01

5 rpm/V: review this winding against the drive

FTM-R116-W01 uses the documented 5 rpm/V speed-coefficient reference. 220 rpm is the documented no-load reference. The separate 120 rpm loaded-speed entry has no complete approved torque/drive/thermal point. Neither entry supplies a continuous torque-speed curve or a speed guarantee at the listed torque. Current conventions and the actual loaded point must be reviewed with the drive.

02

5 and 8.4 N·m use different temperature rises

FTM-R116-W01 documents 5 N·m at 2.04 A RMS for 55°C winding rise, and 8.4 N·m at 3.41 A RMS for 105°C rise. These are temperature rises above ambient, not absolute winding limits or guaranteed output in your housing.

03

26 mm stack: agree the axial envelope before housing design

26 mm is the iron stack. The 36 mm body entry is a drawing reference, not an agreed installation limit. Budget the final body, leads, shaft retention and feedback before freezing the housing. The 83.5 mm bare rotor bore is not the free passage after customer components are installed.

02 / Check the complete envelope

A 26 mm stack. Agree the final axial envelope. Separate space for leads.

Use the bore, body and lead-routing envelope together. Check the order drawing before fixing fits, retention or assembly tolerances.

ParameterDocumented value / definition
Stator outside diameter115 mm0 / -0.10 mm
Stator inside diameter92 mm0 / -0.08 mm
Rotor outside diameter91.3 mm±0.05 mm
Rotor bore83.5 mm+0.04 / 0 mm
Iron stack length26 mm±0.20 mm
Rotor axial length26 mm±0.05 mm
Motor body axial envelope≤36 mmDrawing reference only; final configured envelope and tolerances must be specified before installation.
Power lead length200 mmDrawing reference; customization available for review
FTM-R116-W01 independently composed dimension schematic distinguishing iron stack, rotor bore, body and lead routing
Envelope schematic · Open to inspect the dimension definitions. It is not an approved manufacturing drawing.
FTM-R116-W01 orthographic front CAD view with the modeled lead arrangement
Axial view / rotor bore and stator reference
FTM-R116-W01 orthographic side CAD view with the modeled lead arrangement
Side view / body and modeled lead projection

The FTM-R116 STEP and CAD views describe a shared mechanical reference, not winding internals or verified surface finishes. The CAD including modeled leads spans approximately 59 mm axially. The 200 mm lead-length reference is separate from that modeled envelope. 26 mm is the iron stack. The 36 mm body entry is a drawing reference, not an agreed installation limit. Budget the final body, leads, shaft retention and feedback before freezing the housing.

03 / Match the winding to the drive

Check the 12–80 V winding and the current definition.

A suitable bus voltage alone does not establish compatibility. Review the loaded torque-speed point, current convention, commutation, heat path and protection settings together.

ParameterDocumented value / definition
Drive voltage range12–80 VTypical voltage 48 V; drive matching requires review
Rated output power110 W±10%; documented typical 48 V basis
Speed coefficient5 rpm/V±10%; documented unit
No-load speed220 rpm±10%; not a loaded operating point
Listed loaded speed120 rpm±10%; load/drive/thermal point requires confirmation
Line resistance5.214 Ω±10%; measurement temperature not specified
Line inductance8.444 mH±10%; measurement frequency not specified
Torque constant1.728 N·m/A±10%; current convention must be checked with the drive
Back EMF constant1.98 V·s/rad±10%; electrical convention requires confirmation
Winding connectionY starDocumented connection
Rotor poles40 40 rotor poles; slot count is not specified in the reviewed drawing
Mass829 g±10%; documented value
Rotor inertia382 kg·mm²±10%; documented value
Electrical time constant1.97 ms±10%; documented entry; confirm its definition rather than deriving a drive setting from L/R
Motor constant1.02 N·m/√W±10%; documented value

Plan the customer assembly around the motor kit

The reference geometry depicts a stator and a permanent-magnet rotor with modeled leads. Confirm the supplied lead arrangement, temperature sensor, potting and any accessories on the order drawing. Bearings, a customer shaft, housing, feedback device and servo drive are separate integration requirements, not confirmed included items.

Define stator-to-housing heat transfer, rotor retention, concentricity and air-gap control with your mechanical team. Establish feedback/commutation and temperature-sensor wiring with your drive supplier. No press-fit interference, adhesive process or assembly force is approved by this reference page.

Review the frameless motor installation checklist ↗

Compare this frame’s winding options

FTM-R116: shared mechanical reference, separate drive review.

The listed winding options share the reviewed mechanical reference and revision shown below. Compare documented electrical entries with their conditions; a shared frame does not establish identical cooling, drive settings or interchangeability.

Engineering reviews remain open for the identified windings. This comparison does not confirm a housing fit or electrical setting. Resolve the relevant documentation questions before selection.

FTM-R116-W01 / FTM-R116-W02 / FTM-R116-W03: Axial dimensions are documentation references for configuration discussion. The final body envelope, tolerances and lead exit must be specified on the configuration drawing; these references do not establish installation fit.

On narrow screens, scroll the table to view both winding columns.

Parameter / operating basisFTM-R116-W01 ↗
rev-a
FTM-R116-W02 ↗
rev-a
FTM-R116-W03 ↗
rev-a
Drive voltage range12–80 V12–80 V12–80 V
Speed coefficient5 rpm/V10 rpm/V19 rpm/V
No-load speed220 rpm450 rpm1100 rpm
Listed loaded speed120 rpm320 rpm920 rpm
Line resistance5.214 Ω1.309 Ω0.326 Ω
Line inductance8.444 mH2.106 mH0.527 mH
Torque constant1.728 N·m/A0.863 N·m/A0.431 N·m/A
Back EMF constant1.98 V·s/rad0.99 V·s/rad0.496 V·s/rad
Winding connectionY starY starY star
Mass829 g829 g829 g
Rotor inertia382 kg·mm²382 kg·mm²382 kg·mm²
Continuous / 55°C winding temperature rise5.00 N·m / 2.04 A RMS5.00 N·m / 4.07 A RMS5.00 N·m / 8.14 A RMS
Continuous / 105°C winding temperature rise8.40 N·m / 3.41 A RMS8.40 N·m / 6.82 A RMS8.40 N·m / 13.64 A RMS
Peak / 10 seconds20.90 N·m / 9.13 A RMS20.90 N·m / 18.26 A RMS20.90 N·m / 36.63 A RMS
Peak / 2 seconds32.30 N·m / 18.26 A RMS32.30 N·m / 36.63 A RMS32.30 N·m / 73.15 A RMS

No-load speed is not a loaded operating point. The listed loaded speeds have incomplete load, drive and thermal definitions. Compare torque constants only after checking the current convention; peak durations do not define a repeat/recovery cycle. Equal torque entries are not evidence of equal efficiency or identical test conditions. Use the individual datasheet and submit your loaded torque-speed point for a winding recommendation.

04 / Inspect the reference files

One winding datasheet. One clearly scoped mechanical CAD.

The datasheet identifies FTM-R116-W01; the STEP identifies FTM-R116 mechanical reference geometry. Confirm the applicable revision before using either as an order specification.

STEP / mechanical geometry

Stator & rotor CAD assembly

rev-a · 84.9 KB · Configuration reference · final order drawing required

Applies to: FTM-R116-W01, FTM-R116-W02, FTM-R116-W03 · FTM-R116 / rev-a · Shared mechanical reference; winding data is in each datasheet.

Download STEP
File identity & checksum

ftm-r116-mechanical.stp

6e4258fb76f0dbcca2fd2e12c14ff6094fb3a2a10f53d549130d27928233654c
PDF / winding reference

W01 engineering datasheet

rev-a · 21.5 KB · Configuration reference · final order drawing required

Applies to: FTM-R116-W01 · FTM-R116 / rev-a

Download PDF
File identity & checksum

ftm-r116-w01-datasheet.pdf

b7dde8a4b36bf0d482b3e6882ae5246286eb624f0aac2f2f7e11cbb9b9903f4a
PDF / envelope reference

Mechanical envelope sheet

rev-a · 89.8 KB · Configuration reference · final order drawing required

Applies to: FTM-R116-W01 · FTM-R116 / rev-a

Download PDF
File identity & checksum

ftm-r116-w01-outline.pdf

17be8a109b5049ff41a1aefdcd9d16265302690f79a15f7e490cb77f7ea06d10

Supplier-provided engineering data, checked against the model documentation; not independently measured. The PDFs are independently composed reference documents. CAD export checks do not replace application or supplier revision approval.

05 / Review the configuration you need

Bring the winding, interfaces and leads into one engineering brief.

Customization starts with your constraints and a configuration review. The proposed design, sample requirements, quotation and confirmation drawing are then agreed for the project.

Winding and drive matching

Start from FTM-R116-W01; provide the loaded torque-speed point, DC bus, current convention, continuous duty and timed peaks/recovery. A custom winding is subject to configuration review.

Housing, shaft and axial interfaces

Provide maximum OD, required usable bore, shaft/rotor retention and complete axial/lead space. Agree the final envelope rather than using the reference body entry as an installation limit.

Lead arrangement and sensing

Specify exit direction, actual cable length, connector and temperature/feedback needs. Confirm supplied components and accessories for the quoted configuration.

  1. 01Share the duty and envelope
  2. 02Review winding and interfaces
  3. 03Confirm drawing and sample plan
  4. 04Freeze the order configuration

06 / Resolve the remaining questions

Before you specify FTM-R116-W01.

What does the 26 mm stack mean for FTM-R116-W01 installation?

26 mm is the iron stack. The 36 mm body entry is a drawing reference, not an agreed installation limit. Budget the final body, leads, shaft retention and feedback before freezing the housing. The 83.5 mm bare rotor bore must also accommodate the customer shaft and retention features.

Which continuous torque reference should I use for FTM-R116-W01?

FTM-R116-W01 documents 5 N·m at 2.04 A RMS for 55°C winding rise, and 8.4 N·m at 3.41 A RMS for 105°C rise. These are temperature rises above ambient, not absolute winding limits or guaranteed output in your housing.

Can FTM-R116-W01 repeat its 32.3 N·m peak?

The 20.9 N·m reference belongs to 10 seconds at 9.13 A RMS; 32.3 N·m belongs to 2 seconds at 18.26 A RMS. Repetitive duty requires a defined repeat/recovery cycle, heat path, ambient and drive review.

Does 220 rpm establish a loaded operating point?

220 rpm is the documented no-load reference. The separate 120 rpm loaded-speed entry has no complete approved torque/drive/thermal point. Neither entry supplies a continuous torque-speed curve or a speed guarantee at the listed torque.

What do the FTM-R116-W01 PDF and STEP describe?

The PDF identifies this winding reference; the FTM-R116 STEP is shared mechanical reference geometry for the listed windings. CAD lead shape and neutral colors are not production cable length or finish specifications. The axial envelope remains subject to the final configuration drawing.

Can FTM-R116-W01 be customized, and what should I send?

Request a configuration review with FTM-R116-W01 / rev-a, loaded torque and speed, peak duration/recovery, bus/current definitions, housing heat path, available OD/bore/axial space, lead/sensor needs and quantities. Winding and interface changes, supplied components and delivery terms are agreed for the reviewed configuration.

07 / Start with this model

Request a FTM-R116-W01 fit & winding review.

The form starts with the public model and revision. Add your actual operating point, cooling, envelope and quantities so the response can address the configuration you need.

Samples, MOQ, lead time and pricing are quoted against the reviewed requirements.

Email directly

If the form is unavailable, contact [email protected] or WhatsApp WhatsApp Engineering Support.

Compare other mechanical references in this frame

These references use other axial configurations in the same stator diameter. Listed temperature rises share a label; identical cooling and test conditions have not been established. No replacement equivalence is implied. Use the full selector for other frame sizes.

Model / revisionOD / bore / stackBody maximum / lead spaceDocumented continuous torque
FTM-R114-W01 ↗
rev-a
115 / 83.5 / 13 mm≤23 mm bodyLeads need separate review; documentation discrepancy open.2.5 N·m at 55°C rise4.2 N·m at 105°C rise
FTM-R114-W02 ↗
rev-a
115 / 83.5 / 13 mm≤23 mm bodyLeads need separate review; documentation discrepancy open.2.5 N·m at 55°C rise4.2 N·m at 105°C rise
FTM-R114-W03 ↗
rev-a
115 / 83.5 / 13 mm≤23 mm bodyLeads need separate review; documentation discrepancy open.2.5 N·m at 55°C rise4.2 N·m at 105°C rise
FTM-R115-W01 ↗
rev-a
115 / 83.5 / 20 mm≤30 mm bodyLeads need separate review; documentation discrepancy open.3.9 N·m at 55°C rise6.4 N·m at 105°C rise
FTM-R115-W02 ↗
rev-a
115 / 83.5 / 20 mm≤30 mm bodyLeads need separate review; documentation discrepancy open.3.9 N·m at 55°C rise6.4 N·m at 105°C rise
FTM-R115-W03 ↗
rev-a
115 / 83.5 / 20 mm≤30 mm bodyLeads need separate review; documentation discrepancy open.3.9 N·m at 55°C rise6.4 N·m at 105°C rise

Review this motor inside your assembly

Keep the model revision and stated rating conditions with your installation, drive and cooling requirements.

Look up a model, screen the envelope and compare winding referencesUse the record’s revision and open reviews; a shortlist is not engineering confirmation.