Documented model reference · Custom winding and interfaces available for review.

Frameless motor reference / 50 mm frame

FTM-R101-W0250 mm frameless torque motor

FTM-R101-W02 is a 50 mm frameless motor reference with a 28.5 mm rotor bore and 13 mm iron stack. Its 133 rpm/V winding documents 0.24 N·m at 2.73 A RMS under the 55°C winding-rise condition. Use the references to discuss your winding, housing and duty cycle.

rev-a · Documentation reviewed 2026-10-31 · Standard configuration subject to order confirmation

Mechanical referenceFTM-R101
FTM-R101-W02 isometric CAD view showing the stator, rotor bore and modeled power leads
Actual CAD geometry · Neutral engineering palette · Product finishes are not verified. Shared mechanical reference across the listed winding options; not a winding-detail image.
Stator OD
50mm
Rotor bore
28.5mm
Iron stack
13mm
Motor body reference
≤22mm

01 / Choose the operating basis

Keep temperature rise and peak duration with the torque.

The same winding has different documented ratings under different limits. Start with your duty cycle and housing heat path.

Continuous torque by winding temperature rise

RiseTorqueRMS current
55°C0.24 N·m2.73 A
105°C0.40 N·m4.51 A

Peak torque by duration

DurationTorqueRMS peak current
10 s1.05 N·m12.21 A
2 s1.86 N·m24.53 A
FTM-R101-W02 discrete comparison of 55 and 105 degree temperature-rise ratings and 2 and 10 second peak torque
Separate scales compare the continuous pair and the peak pair. These are documented entries, not a torque–speed curve.

Documented performance and electrical entries are generally ±10%. Temperature rise is relative to ambient, not the absolute winding temperature. The source documentation does not fully define the housing heat sink, ambient temperature or repeated-peak recovery cycle. These ratings require application review; they are not independently measured results. Reference publication does not establish a configured production rating.

Documented dimensions and ratings support initial selection. Confirm the configured winding, installation drawing and operating conditions for your application.

01

133 rpm/V: review this winding against the drive

FTM-R101-W02 uses the documented 133 rpm/V speed-coefficient reference. 6270 rpm is the documented no-load reference. The separate 5907 rpm loaded-speed entry has no complete approved torque/drive/thermal point. Neither entry supplies a continuous torque-speed curve or a speed guarantee at the listed torque. Current conventions and the actual loaded point must be reviewed with the drive.

02

0.24 and 0.4 N·m use different temperature rises

FTM-R101-W02 documents 0.24 N·m at 2.73 A RMS for 55°C winding rise, and 0.4 N·m at 4.51 A RMS for 105°C rise. These are temperature rises above ambient, not absolute winding limits or guaranteed output in your housing.

03

28.5 mm bore: reserve the shaft, retention and lead space

13 mm is the iron stack, separate from the drawing body reference of 22 mm and the CAD lead projection. Reserve space for shaft retention, leads and feedback before freezing the housing. The 28.5 mm bare rotor bore is not the free passage after customer components are installed.

02 / Check the complete envelope

A 13 mm stack. A 22 mm body reference. Separate space for leads.

Use the bore, body and lead-routing envelope together. Check the order drawing before fixing fits, retention or assembly tolerances.

ParameterDocumented value / definition
Stator outside diameter50 mm0 / -0.07 mm
Stator inside diameter34 mm0 / -0.06 mm
Rotor outside diameter33.4 mm±0.05 mm
Rotor bore28.5 mm+0.03 / 0 mm
Iron stack length13 mm±0.20 mm
Rotor axial length13 mm±0.05 mm
Motor body axial envelope≤22 mmMaximum; excludes lead routing; confirm the configured installation drawing.
Power lead length200 mmDrawing reference; customization available for review
FTM-R101-W02 independently composed dimension schematic distinguishing iron stack, rotor bore, body and lead routing
Envelope schematic · Open to inspect the dimension definitions. It is not an approved manufacturing drawing.
FTM-R101-W02 orthographic front CAD view with the modeled lead arrangement
Axial view / rotor bore and stator reference
FTM-R101-W02 orthographic side CAD view with the modeled lead arrangement
Side view / body and modeled lead projection

The FTM-R101 STEP and CAD views describe a shared mechanical reference, not winding internals or verified surface finishes. The CAD including modeled leads spans approximately 44.65 mm axially. The 200 mm lead-length reference is separate from that modeled envelope. 13 mm is the iron stack, separate from the drawing body reference of 22 mm and the CAD lead projection. Reserve space for shaft retention, leads and feedback before freezing the housing.

03 / Match the winding to the drive

Check the 12–48 V winding and the current definition.

A suitable bus voltage alone does not establish compatibility. Review the loaded torque-speed point, current convention, commutation, heat path and protection settings together.

ParameterDocumented value / definition
Drive voltage range12–48 VTypical voltage 48 V; drive matching requires review
Rated output power170 W±10%; documented typical 48 V basis
Speed coefficient133 rpm/V±10%; documented unit
No-load speed6270 rpm±10%; not a loaded operating point
Listed loaded speed5907 rpm±10%; load/drive/thermal point requires confirmation
Line resistance0.437 Ω±10%; measurement temperature not specified
Line inductance0.385 mH±10%; measurement frequency not specified
Torque constant0.061 N·m/A±10%; current convention must be checked with the drive
Back EMF constant0.071 V·s/rad±10%; electrical convention requires confirmation
Winding connectionY starDocumented connection
Slots / rotor poles18 / 20 Documented arrangement
Mass100 g±10%; documented value
Rotor inertia5 kg·mm²±10%; documented value
Electrical time constant1.08 ms±10%; documented value
Motor constant0.125 N·m/√W±10%; documented value

Plan the customer assembly around the motor kit

The reference geometry depicts a stator and a permanent-magnet rotor with modeled leads. Confirm the supplied lead arrangement, temperature sensor, potting and any accessories on the order drawing. Bearings, a customer shaft, housing, feedback device and servo drive are separate integration requirements, not confirmed included items.

Define stator-to-housing heat transfer, rotor retention, concentricity and air-gap control with your mechanical team. Establish feedback/commutation and temperature-sensor wiring with your drive supplier. No press-fit interference, adhesive process or assembly force is approved by this reference page.

Review the frameless motor installation checklist ↗

Compare this frame’s winding options

FTM-R101: shared mechanical reference, separate drive review.

The listed winding options share the reviewed mechanical reference and revision shown below. Compare documented electrical entries with their conditions; a shared frame does not establish identical cooling, drive settings or interchangeability.

Engineering reviews remain open for the identified windings. This comparison does not confirm a housing fit or electrical setting. Resolve the relevant documentation questions before selection.

FTM-R101-W01 / FTM-R101-W02: Documented dimensions and ratings support initial selection. Confirm the configured winding, installation drawing and operating conditions for your application.

On narrow screens, scroll the table to view both winding columns.

Parameter / operating basisFTM-R101-W01 ↗
rev-a
FTM-R101-W02 ↗
rev-a
Drive voltage range12–48 V12–48 V
Speed coefficient66 rpm/V133 rpm/V
No-load speed3080 rpm6270 rpm
Listed loaded speed2827 rpm5907 rpm
Line resistance1.75 Ω0.437 Ω
Line inductance1.53 mH0.385 mH
Torque constant0.123 N·m/A0.061 N·m/A
Back EMF constant0.142 V·s/rad0.071 V·s/rad
Winding connectionY starY star
Mass100 g100 g
Rotor inertia5 kg·mm²5 kg·mm²
Continuous / 55°C winding temperature rise0.24 N·m / 1.36 A RMS0.24 N·m / 2.73 A RMS
Continuous / 105°C winding temperature rise0.40 N·m / 2.28 A RMS0.40 N·m / 4.51 A RMS
Peak / 10 seconds1.05 N·m / 6.16 A RMS1.05 N·m / 12.21 A RMS
Peak / 2 seconds1.86 N·m / 12.21 A RMS1.86 N·m / 24.53 A RMS

No-load speed is not a loaded operating point. The listed loaded speeds have incomplete load, drive and thermal definitions. Compare torque constants only after checking the current convention; peak durations do not define a repeat/recovery cycle. Equal torque entries are not evidence of equal efficiency or identical test conditions. Use the individual datasheet and submit your loaded torque-speed point for a winding recommendation.

04 / Inspect the reference files

One winding datasheet. One clearly scoped mechanical CAD.

The datasheet identifies FTM-R101-W02; the STEP identifies FTM-R101 mechanical reference geometry. Confirm the applicable revision before using either as an order specification.

STEP / mechanical geometry

Stator & rotor CAD assembly

rev-a · 186.3 KB · Configuration reference · final order drawing required

Applies to: FTM-R101-W01, FTM-R101-W02 · FTM-R101 / rev-a · Shared mechanical reference; winding data is in each datasheet.

Download STEP
File identity & checksum

ftm-r101-mechanical.stp

508e9c19205360734d037727ef2e26f9a8a1f06c7f66c34cd4a8fdfdebe17d16
PDF / winding reference

W02 engineering datasheet

rev-a · 21.3 KB · Configuration reference · final order drawing required

Applies to: FTM-R101-W02 · FTM-R101 / rev-a

Download PDF
File identity & checksum

ftm-r101-w02-datasheet.pdf

e701d370303c4342d463527094f4407ba1155557d67e75949b96f75bf0628349
PDF / envelope reference

Mechanical envelope sheet

rev-a · 89.8 KB · Configuration reference · final order drawing required

Applies to: FTM-R101-W02 · FTM-R101 / rev-a

Download PDF
File identity & checksum

ftm-r101-w02-outline.pdf

837dade8e9ae5ba433d4c7ee8eacd1eb13bb87153e18bd48a7943f62da61c450

Supplier-provided engineering data, checked against the model documentation; not independently measured. The PDFs are independently composed reference documents. CAD export checks do not replace application or supplier revision approval.

05 / Review the configuration you need

Bring the winding, interfaces and leads into one engineering brief.

Customization starts with your constraints and a configuration review. The proposed design, sample requirements, quotation and confirmation drawing are then agreed for the project.

Winding and drive matching

Start from FTM-R101-W02; provide the loaded torque-speed point, DC bus, current convention, continuous duty and timed peaks/recovery. A custom winding is subject to configuration review.

Housing, shaft and axial interfaces

Provide maximum OD, required usable bore, shaft/rotor retention and complete axial/lead space. Confirm fits and tolerances on the configuration drawing.

Lead arrangement and sensing

Specify exit direction, actual cable length, connector and temperature/feedback needs. Confirm supplied components and accessories for the quoted configuration.

  1. 01Share the duty and envelope
  2. 02Review winding and interfaces
  3. 03Confirm drawing and sample plan
  4. 04Freeze the order configuration

06 / Resolve the remaining questions

Before you specify FTM-R101-W02.

What does the 13 mm stack mean for FTM-R101-W02 installation?

13 mm is the iron stack, separate from the drawing body reference of 22 mm and the CAD lead projection. Reserve space for shaft retention, leads and feedback before freezing the housing. The 28.5 mm bare rotor bore must also accommodate the customer shaft and retention features.

Which continuous torque reference should I use for FTM-R101-W02?

FTM-R101-W02 documents 0.24 N·m at 2.73 A RMS for 55°C winding rise, and 0.4 N·m at 4.51 A RMS for 105°C rise. These are temperature rises above ambient, not absolute winding limits or guaranteed output in your housing.

Can FTM-R101-W02 repeat its 1.86 N·m peak?

The 1.05 N·m reference belongs to 10 seconds at 12.21 A RMS; 1.86 N·m belongs to 2 seconds at 24.53 A RMS. Repetitive duty requires a defined repeat/recovery cycle, heat path, ambient and drive review.

Does 6270 rpm establish a loaded operating point?

6270 rpm is the documented no-load reference. The separate 5907 rpm loaded-speed entry has no complete approved torque/drive/thermal point. Neither entry supplies a continuous torque-speed curve or a speed guarantee at the listed torque.

What do the FTM-R101-W02 PDF and STEP describe?

The PDF identifies this winding reference; the FTM-R101 STEP is shared mechanical reference geometry for the listed windings. CAD lead shape and neutral colors are not production cable length or finish specifications. Confirm the selected mechanical revision and configuration before installation.

Can FTM-R101-W02 be customized, and what should I send?

Request a configuration review with FTM-R101-W02 / rev-a, loaded torque and speed, peak duration/recovery, bus/current definitions, housing heat path, available OD/bore/axial space, lead/sensor needs and quantities. Winding and interface changes, supplied components and delivery terms are agreed for the reviewed configuration.

07 / Start with this model

Request a FTM-R101-W02 fit & winding review.

The form starts with the public model and revision. Add your actual operating point, cooling, envelope and quantities so the response can address the configuration you need.

Samples, MOQ, lead time and pricing are quoted against the reviewed requirements.

Email directly

If the form is unavailable, contact [email protected] or WhatsApp WhatsApp Engineering Support.

Compare other mechanical references in this frame

These references use other axial configurations in the same stator diameter. Listed temperature rises share a label; identical cooling and test conditions have not been established. No replacement equivalence is implied. Use the full selector for other frame sizes.

Model / revisionOD / bore / stackBody maximum / lead spaceDocumented continuous torque
FTM-R102-W01 ↗
rev-a
50 / 28.5 / 20 mm≤29 mm bodyLeads need separate review; documentation discrepancy open.0.37 N·m at 55°C rise0.61 N·m at 105°C rise
FTM-R102-W02 ↗
rev-a
50 / 28.5 / 20 mm≤29 mm bodyLeads need separate review; documentation discrepancy open.0.37 N·m at 55°C rise0.61 N·m at 105°C rise
FTM-R103-W01 ↗
rev-a
50 / 28.5 / 26 mm≤35 mm bodyLeads need separate review; documentation discrepancy open.0.48 N·m at 55°C rise0.8 N·m at 105°C rise
FTM-R103-W02 ↗
rev-a
50 / 28.5 / 26 mm≤35 mm bodyLeads need separate review; documentation discrepancy open.0.48 N·m at 55°C rise0.8 N·m at 105°C rise

Review this motor inside your assembly

Keep the model revision and stated rating conditions with your installation, drive and cooling requirements.

Look up a model, screen the envelope and compare winding referencesUse the record’s revision and open reviews; a shortlist is not engineering confirmation.